4. Installation Instructions
Mounting
• After selecting the proper location for your CO Alarm and wiring the
AC Quick-Connector harness, attach the mounting plate to the elec-
trical box. To ensure aesthetic alignment of the alarm with the hall-
way, or wall, the “A” line on the mounting plate must be parallel with
the hallway when ceiling mounted or horizontal when wall mounted.
• Pull the AC Quick-Connector through the center hole in the mounting
plate and secure the bracket, making sure that the mounting screws
are positioned in the small ends of the keyholes before tightening.
• Plug the AC Quick-Connector into the back of the alarm, making sure
that the locks on the connector snap into the unit. Push the excess
wire back into the electrical box through
the hole in the center of the mounting
plate.
• Install the alarm on the mounting plate
and twist the alarm in the direction of
the “ON” arrow on the cover until the
alarm ratchets into place (this ratcheting
function allows for aesthetic alignment).
Note: The alarm will mount to the
bracket in 4 positions (every 90 degrees).
• Turn on the AC power. The green AC
Power On Indicator should be lit when
the alarm is operating from AC power.
• Pull the Battery Pull Tab (yellow tab pro-
truding from unit) completely out of
unit. This will automatically connect the
battery.
AC Quick Connector
Post Locations