120 V AC and 9 V Battery BackupCombination Smoke &Carbon Monoxide Alarmwith Voice Alarm System, Hush®, and Peak Level MemoryFor your convenience
The Hush®feature can be used repeatedly until the airhas been cleared of the condition causing the alarm. While the unit is in Hush®mode, pushing the
Tamper Resist FeatureTo make the Smoke/CO alarm somewhat tamperresistant, a tamper resist feature has been provided.Activate the tamper resist feature
21If the tamper resist feature has been activated, refer totamper resist feature description on page 19 forremoval instructions.Remove the alarm from
General CO InformationCarbon monoxide (CO) is a colorless, odorless, andtasteless poison gas that can be fatal when inhaled. COinhibits the blood’s c
Possible Sources of COCO can be produced when burning any fossil fuel, suchas gasoline, propane, natural gas, oil and wood. It canbe produced by any
2726The fo l l owin g conditions can result in transient COs i t u a t i o n s :Excessive spillage or reverse venting of fuel-burn i n gappliances cau
2928• Go to a predetermined meeting place. When twopeople have arrived, one should leave to call 911from a neighbor’s home, and the other should stay
5 Year Limited WarrantyKidde warrants that the enclosed alarm (but not thebattery) will be free from defects in material andworkmanship or design unde
N o t e s33Also, Kidde makes no warranty, express or implied,written or oral, including that of merchantability or fitness for any particular purpose,
Thank you for purchasing the Kidde Combination Smoke and Carbon Monoxide Alarm.Model # KN-COSM-IBCA (with battery backup)Model # KN-COSM-ICA (without
32I l l u s t r a t i o n sI l l u s t r a t i o n sFRONTBACKRed LED LightGreen LED LightTest/Reset/Hush® ButtonAlarmSounder
• Voice Message System that alerts user to thefollowing additional conditions:• System announces, "Hush®mode on! Mode Hush®activé!" when th
Smoke AlarmThe smoke alarm constantly monitors the air for products ofcombustion that are produced when something is burning orsmoldering. When smoke
Recommended Installation LocationsWARNING: This product is intended for use inordinary indoor locations of family living units.It is not designed to m
Locations To AvoidWARNING: Do not install in garages, kitchens, furnacerooms or bathrooms! Install at least 1.5 m (5’) awayfrom any fuel burning appl
WiringWiring Requirements:• This Smoke/CO Alarm should be installed on a CSAlisted or recognized junction box. All connectionsshould be made by a qua
15MountingC AU T I O N : This unit is sealed. The cover is not re m ovabl e .• Seven (7) years after initial power up, this unit will "chirp"