Kidde KN-COSM-IBCA Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Kohlenmonoxid (CO) -Detektoren Kidde KN-COSM-IBCA herunter. Kidde KN-COSM-IBCA User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 18
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
120 V AC and 9 V Battery Backup
C
ombination
S
moke &
C
arbon
M
onoxide
A
larm
with Voice Alarm System, Hush
®
, and Peak Level Memory
For your convenience, write down the following information. If you call
our consumer hotline, these are the first questions you will be asked:
Alarm Model Number (located on back of alarm):
Date of Manufacture (located on the back of the alarm):
Date of Purchase:
Where Purchased:
Alarm Assembly Number (located on the back of the alarm):
A l a r m Manual
Model
KN-COSM-ICA
Model
KN-COSM-IBCA
Custom Assembled in China with U.S. and Foreign Components. Patents Pending
130 Esna Park Drive, Markham ON L3R 1E3
Consumer Hotline:
1-800-880-6788
w w w. k i d d e . c a
Maximum protection
only an Interconnectable System can offer:
Every floor... every living space... any place where a crisis could
begin, needs the added security of an interconnectable life safety
warning system! ANY unit that senses a problem automatically
triggers ALL units through-out the home immediately, allowing
extra time for escape.
Installing the Interconnectable System is simple:
Unlike competitive products, the Interconnectable System requires
no complex wiring or relay switches to separate alarms. Just direct
connect and you're done!
This Smoke & CO Alarm interconnects with up to 24 devices
directly. Use with Kidde Pro, Fyrnetics and Lifesaver Smoke
Alarms, including:
•1235CA Series •1285CA Series •PI2000CA •KN-COSM-ICA
•1275CA Series •PE120CA •HD135 •KN-COSM-IBCA
For more information about compatible interconnect units and their
functionality in an interconnect system, visit our web site at:
www.kidde.ca
SINGLE AND/OR MULTIPLE STATION
CARBON MONOXIDE ALARM
SINGLE AND/OR MULTIPLE STATION
SMOKE ALARM
SINGLE AND/OR MULTIPLE STATION
CARBON MONOXIDE ALARM
(model KN-COSM-IBCA only)
810-1692_RevD_119-133_MAN_ENG 10/7/03 4:41 PM Page 34
Seitenansicht 0
1 2 3 4 5 6 ... 17 18

Inhaltsverzeichnis

Seite 1 - A l a r m Manual

120 V AC and 9 V Battery BackupCombination Smoke &Carbon Monoxide Alarmwith Voice Alarm System, Hush®, and Peak Level MemoryFor your convenience

Seite 2 - C o n t e n t s

The Hush®feature can be used repeatedly until the airhas been cleared of the condition causing the alarm. While the unit is in Hush®mode, pushing the

Seite 3 - I l l u s t r a t i o n s

Tamper Resist FeatureTo make the Smoke/CO alarm somewhat tamperresistant, a tamper resist feature has been provided.Activate the tamper resist feature

Seite 4

21If the tamper resist feature has been activated, refer totamper resist feature description on page 19 forremoval instructions.Remove the alarm from

Seite 5

General CO InformationCarbon monoxide (CO) is a colorless, odorless, andtasteless poison gas that can be fatal when inhaled. COinhibits the blood’s c

Seite 6

Possible Sources of COCO can be produced when burning any fossil fuel, suchas gasoline, propane, natural gas, oil and wood. It canbe produced by any

Seite 7 - I n s t a l l a t i o n

2726The fo l l owin g conditions can result in transient COs i t u a t i o n s :Excessive spillage or reverse venting of fuel-burn i n gappliances cau

Seite 8

2928• Go to a predetermined meeting place. When twopeople have arrived, one should leave to call 911from a neighbor’s home, and the other should stay

Seite 9 - FIGURE 2

5 Year Limited WarrantyKidde warrants that the enclosed alarm (but not thebattery) will be free from defects in material andworkmanship or design unde

Seite 10 - O p e r a t i o n

N o t e s33Also, Kidde makes no warranty, express or implied,written or oral, including that of merchantability or fitness for any particular purpose,

Seite 11

Thank you for purchasing the Kidde Combination Smoke and Carbon Monoxide Alarm.Model # KN-COSM-IBCA (with battery backup)Model # KN-COSM-ICA (without

Seite 12 - FIGURE 4

32I l l u s t r a t i o n sI l l u s t r a t i o n sFRONTBACKRed LED LightGreen LED LightTest/Reset/Hush® ButtonAlarmSounder

Seite 13 - M a i n t e n a n c e

• Voice Message System that alerts user to thefollowing additional conditions:• System announces, "Hush®mode on! Mode Hush®activé!" when th

Seite 14

Smoke AlarmThe smoke alarm constantly monitors the air for products ofcombustion that are produced when something is burning orsmoldering. When smoke

Seite 15

Recommended Installation LocationsWARNING: This product is intended for use inordinary indoor locations of family living units.It is not designed to m

Seite 16 - F i r e Safety

Locations To AvoidWARNING: Do not install in garages, kitchens, furnacerooms or bathrooms! Install at least 1.5 m (5’) awayfrom any fuel burning appl

Seite 17 - Wa r r a n t y

WiringWiring Requirements:• This Smoke/CO Alarm should be installed on a CSAlisted or recognized junction box. All connectionsshould be made by a qua

Seite 18 - N o t e s

15MountingC AU T I O N : This unit is sealed. The cover is not re m ovabl e .• Seven (7) years after initial power up, this unit will "chirp"