For your convenience, write down the following
information. If you call our Consumer Hotline,
these are the first questions you will be asked.
Smoke Alarm Model Number
(located on back of alarm):
Date Code (located on back of alarm).
National Fire Protection Association
(NFPA) and the manufacturer
recommends replacing this alarm
ten years from the date code:
Date of Purchase:
Where Purchased:
AC Wire-in Single and/or Multiple Station (up to 24 Devices)
Photoelectric/Ionization Smoke Alarm with 9 Volt Battery
Back Up and “HUSH” Control to temporarily silence nuisance
alarms.
Thank you for purchasing this smoke alarm. It is an important part of
your family’s home safety plan. You can trust this product to provide
the highest quality safety protection. We know you expect nothing less
when the lives of your family are at stake. Kidde alarms and accessories
CAN ONLY BE interconnected with other Kidde alarms and accessories
as well as specified brands and models of interconnect compatible
alarms. Connection of Kidde products to a non-specified manufactur-
er’s interconnect system, or connection with non-specified equipment
from another manufacturer into an existing Kidde system could result
in nuisance alarming, failure to alarm, or damage to one or all of the
devices in the interconnect system. Refer to the User’s Guide supplied
with each Kidde product for interconnect compatible models, brands,
and devices. Refer to the wiring instructions in section 3 for NFPA initi-
ating device limits.
Smoke Alarm User’s Guide
820-0905 REV. D 06/09
1475-7205-00
PI2010
For model: PI2010
1475-7205-00(820-0905-EN).indd 11475-7205-00(820-0905-EN).indd 1 2009.11.27 2:00:43 PM2009.11.27 2:00:43 PM
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - Smoke Alarm User’s Guide

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.Smoke Al

Seite 2

Hush Condition: The red LED will flash every 10 seconds as long as the alarm is in Hush mode.Low Battery Condition: The red LED flash will be acco

Seite 3 - FIGURE 4

more information refer to section 4, OPERATION AND TESTING.If the alarm does sound, check for fires first. If a fire is discovered, get out and call

Seite 4 - 2. LOCATIONS TO AVOID

tery (lithium batteries may also be used). A fresh battery should last for one year under normal operating conditions. This alarm has a low battery

Seite 5 - 3. INSTALLATION INSTRUCTIONS

(associated with fast flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible fire particles (associ-ated wit

Seite 6

and in the kitchen, basement and garage. Know how to use a fire extinguisher prior to an emergency.• Current studies have shown smoke alarms may not a

Seite 7 - MOUNTING INSTRUCTIONS

warning protection for those areas separated by a door from the areas protected by the required smoke alarms. For this reason, it is recommended that

Seite 8 - FIGURE 7

TEN YEAR LIMITED WARRANTYKidde warrants to the original purchaser that the enclosed smoke alarm (but not the battery) will be free from defects in mat

Seite 9 - 4. OPERATION AND TESTING

The ion portion of this alarm detects products of combustion using the ionization technique. It contains 0.9 microcurie of Americium 241, a radioactiv

Seite 10 - 5. NUISANCE ALARMS

• Locate an alarm in every sleeping room.• Locate an alarm in every room where electrical appliances are operated (i.e. portable heaters or humidi-f

Seite 11 - 6. MAINTENANCE

at a minimum of 4” (10 cm) and a maximum of 12” (30.5 cm) below the ceiling (see figure 1).• Install Smoke Alarms on sloped, peaked or cathedral ceil

Seite 12 - CLEANING YOUR ALARM

• In very humid areas. Moisture or steam can cause nuisance alarms.• In insect-infested areas.• Smoke alarms should not be installed within 3 ft (.

Seite 13 - 8. GOOD SAFETY HABITS

in place to make certain that the red wire cannot contact any metal parts or the electrical box.• When alarms are interconnected, all interconnected

Seite 14 - 10. NFPA REQUIRED PROTECTION

Black Hot Side of AC LineWhite Neutral Side of AC LineRed Interconnect Lines (Red Wires) of Other Units in the Multiple Statio

Seite 15 - 12. SERVICE AND WARRANTY

tion of the “ON” arrow on the cover until the alarm ratchets into place (this ratcheting function allows for aesthetic alignment).7. Turn on the AC po

Seite 16 - TEN YEAR LIMITED WARRANTY

4. OPERATION AND TESTINGOPERATION: The smoke alarm is operating once AC power is applied, a fresh battery is installed and testing is complete. When