Manual P/N 820-1493 Rev. B 0930-7203-00SIGNALINGLISTEDULATTENTION: Please take a few minutes to thoroughly read thisuser’s guide which should be save
4. Operation and TestingOPERATION: The smoke alarm is operating once a fresh battery isinstalled and testing is complete. When products of combustion
Smoke alarms are designed to minimize nuisance alarms. Cigarettesmoke will not normally set off the alarm, unless the smoke is blowndirectly into the
USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR i9040RV ANDi9060RV SMOKE ALARM BATTERY REPLACEMENT:Alkaline type: ENERGIZER 522; DURACELL MN1604, MX1604;
7. Limitations of Smoke AlarmsWARNING: PLEASE READ CAREFULLY AND THOROUGHLY• NFPA 72 states: Fire-warning equipment for residential occupanciesare ca
7. Limitations of Smoke Alarms• If the alarm is located outside the sleeping room or on a differentfloor, it may not wake up a sound sleeper.• The u
Ionization type smoke alarms use a very small amount of a radioactive ele-ment in the sensing chamber to enable detection of visible and invisiblecomb
11. CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL)Ionization type smoke alarms use a very small amount of a radioac-tive element in the se
12. Service and WarrantyLIMITED WARRANTYKidde warrants to the original purchaser that the enclosed smoke alarm willbe free from defects in material an
QUESTIONS OR FOR MORE INFORMATIONCall our Consumer Hotline at 1-800-880-6788 or contact us at our website at www.kidde.comKidde, 1016 Corporate Park D
Smoke Alarm ProcedureNEVER IGNORE THE SOUND OF THE ALARM!Smoke alarms are designed to minimize false alarms. Cigarettesmoke will not normally set off
Welcomei9030, i9040, i9040RV, i9050, i9060, i9060RV, - 9 Volt BatteryOperated Smoke Alarm with “HUSH” Control to temporarilysilence nuisance alarms.i9
Contents of This User’s Guide1. Recommended Locations for Smoke Alarms2. Locations to avoid3. Installation Instructions4. Operation and testing5. Nuis
• Locate the first alarm in the immediatearea of the sleeping rooms. Try to monitorthe exit path as the sleeping rooms areusually farthest from the ex
1. Recommended Locations for Smoke Alarms• Put smoke alarms at both ends of a hallway or large room if the hall-way or room is more than 30 ft (9.1 m)
• In the garage. Products of combustion are present when you startyour automobile.• Less than 4” (10cm) from the peak of an “A” frame type ceiling.• I
3. Installation InstructionsFIGURE 5FIGURE 5AAAFIGURE 6FIGURE 6AFIGURE 7FIGURE 7AFIGURE 8FIGURE 9i9030 mountingbracket shownmountingbracket for alloth
3. Installation InstructionsMOUNTING INSTRUCTIONSCAUTION: This unit is sealed. The cover is not removable!1. Remove the mounting plate from the back o