Kidde HD135 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Rauchmelder Kidde HD135 herunter. Kidde HD135 User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
AC Wire-in Single and/or Multiple Station (up to 24 Devices) Heat Alarm
with 9 Volt Battery Back Up, 135ºF fixed temperature.
Thank you for purchasing this heat alarm. It is an important part of your family’s
home safety plan. You can trust this product to provide the highest quality safe-
ty protection. We know you expect nothing less when the lives of your family
are at stake. Kidde alarms and accessories CAN ONLY BE interconnected with
other Kidde alarms and accessories as well as specified brands and models of
interconnect compatible alarms. Connection of Kidde products to a non-speci-
fied manufacturer’s interconnect system, or connection with non-specified
equipment from another manufacturer into an existing Kidde system could result
in nuisance alarming, failure to alarm, or damage to one or all of the devices in
the interconnect system. Refer to the User’s Guide supplied with each Kidde
product for interconnect compatible models, brands, and devices. Refer to the
wiring instructions in section 3 for NFPA initiating device limits
For model: HD135F
820-0917-EN Rev. D
1000-7211-01
HD135F
For your convenience, write down the following information. If you call
our Consumer Hotline, these are the first questions you will be asked.
Heat Alarm Model Number
(located on back of alarm):
Date Code (located on back of alarm): The
National Fire Protection Association (NFPA)
and the manufacturer recommend replacing
this alarm ten years from the date code.
Date of Purchase:
Where Purchased:
Heat Alarm User’s Guide
1000-7211-01(820-0917-EN D)_V2.qxd:_ 2011.7.7 2:50 PM Page 1
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - Heat Alarm User’s Guide

AC Wire-in Single and/or Multiple Station (up to 24 Devices) Heat Alarmwith 9 Volt Battery Back Up, 135ºF fixed temperature.Thank you for purchasing t

Seite 2 - 1. SPECIFICATIONS

6. FALSE ALARMSTo avoid false alarms,DO NOT USE WHERE ROOM TEMPERATURES WILL EXCEED100º F.Heat alarms respond only to heat. They do not detect smoke.

Seite 3 - FIGURE 2

This smoke alarm uses a 9V carbon backup battery (alkaline and lithium batteriesmay also be used). A fresh battery should last for one year under norm

Seite 4 - 3. LOCATIONS TO AVOID

8. LIMITATIONS OF HEAT ALARMSWARNING: PLEASE READ CAREFULLY AND THOROUGHLY• HEAT ALARMS ARE NOT DESIGNED TO PROTECT LIFE SAFETY AGAINSTFIRE AND SMOKE

Seite 5 - 4. INSTALLATION INSTRUCTIONS

9. GOOD SAFETY HABITSDEVELOP AND PRACTICE A PLAN OF ESCAPE• Install and maintain Fire extinguishers on every level of the home and in thekitchen, base

Seite 6 - BATTERY INSTALLATION

• Call the fire department from your neighbor’s home - not from yours!• Don’t return to your home until the fire officials say that it is all right to

Seite 7

11. CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIREMARSHAL)“Early warning fire detection is best achieved by the installation of fire detectionequip

Seite 8

FIVE YEAR LIMITED WARRANTYKIDDE Safety warrants to the original purchaser that the enclosed heat alarm (but notthe battery) will be free from defects

Seite 9 - 5. OPERATION AND TESTING

WARNING! BATTERY DOOR WILL NOT CLOSE UNLESS A BATTERY IS PRES-ENT. REMOVAL OF THE HEAT ALARM BATTERY AND DISCONNECTING ORLOSS OF AC POWER WILL RENDER

Seite 10 - 6. FALSE ALARMS

Note A: Maximum coverage established by U.L. is based on providing equalresponse time as sprinkler devices spaced at 10-Ft intervals (100 Sq/Ft) on a

Seite 11 - CLEANING YOUR ALARM

of alarms shall be spaced and locatedwithin 3 ft (0.9m) of the peak of theceiling measured horizontally” (seefigure 3).• In rooms with open joists orb

Seite 12 - 8. LIMITATIONS OF HEAT ALARMS

• In an area where the temperature may fall below -20ºF or rise above 100ºF.• Near fluorescent lights – electronic "noise" may cause nuisanc

Seite 13 - 9. GOOD SAFETY HABITS

• When mixing models which have battery backup (1275, 1276, 1285, 1296,i12040, i12040A, i12060, i12060A, i12080, i12080A, i4618, i4618A, PE120,P12040

Seite 14 - 10. NFPA REQUIRED PROTECTION

MOUNTING INSTRUCTIONSCAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOVABLE!1.Remove the trim ring from the back of the alarm by holding the trim r

Seite 15 - 12. SERVICE AND WARRANTY

7.Install the alarm on the trim ring with the indicating marks aligned and rotatethe alarm in the direction of the “ON” arrow on the cover until the a

Seite 16 - FIVE YEAR LIMITED WARRANTY

5. OPERATION AND TESTINGOPERATION: The heat alarm is operating once AC power is applied, fresh batter-ies are installed and testing is complete. When

Kommentare zu diesen Handbüchern

Keine Kommentare